Alfa protective slide gates close process or building openings to help prevent the propagation of a passing shock wave. They are designed and manufactured with reference to GOST R 56296-2014 and the requirements of the individual facility.


The base model specified in the product passport is USHZ 40-560. The purchaser specifies plate thickness and configuration according to design loads, opening size and operating conditions. Manual, electric-motor and pneumatic-cylinder actuation are available. The VBI non-sparking option uses bronze wheels, brass cladding on the slide plate and copper washers at rod connections to reduce sparking risk.
Purpose and Configuration
- Protective closure of process or building openings in explosion-hazardous facilities.
- Manufacture to Alfa technical specifications and project requirements.
- Manual, electric or pneumatic movement.
- VBI non-sparking configuration for sensitive areas.
- Explosion-protected electrical components and closed-position signalling as specified by the project.
USHZ 40-560 Specifications
| Parameter | Value |
|---|---|
| Slide plate size | 560 x 560 mm |
| Plate thickness | At least 40 mm; final thickness specified by the purchaser and project |
| Base thickness | At least 20 mm |
| Minimum guide section thickness | At least 10 mm |
| Guide fasteners | At least four M16 bolts |
| Actuation system supply | 24 V DC |
| Closed-position indicator supply | 24 V DC |
| Compressed air | Clean, dried air; inlet pressure limited by the regulator setting |
| Operating conditions | Protected from direct precipitation; +5 to +40 degrees C |
| Warranty | 24 months, subject to installation, operation, storage and transport requirements |
| Average service life | 10 years |
Adjustment and Safety
The pneumatic version allows adjustment of pressure and travel speed. Pressure determines opening and closing force; flow controls determine speed. Both must be set for the facility's operating conditions to reduce injury risks.
Use only clean, conditioned air, service the filter-regulator regularly and keep the lower guide free of foreign objects. Prevent movement from starting while an operator's hand is inside the recess.
Operating Videos
Frequently Asked Questions
Can plate thickness be changed?
Yes. The purchaser specifies thickness and configuration to suit the opening, project and required resistance.
Which drives are available?
Manual movement, an electric motor or a pneumatic cylinder. Automated systems use 24 V DC and explosion-protected components as specified.
What is the VBI configuration?
A non-sparking design using bronze wheels, brass plate cladding and copper washers at rod connections.