If there is no documentary evidence, do not assume that testing took place. Check four points before specifying or purchasing a product.
The Russian article references Federal Laws No. 412-FZ of 28 December 2013 and No. 184-FZ, Articles 21 and 31, and GOST R 57471-2017 clauses 9.4.1, 9.5.1, 9.5.4, 9.7.1, 9.9.5.1, 9.9.5.2, 9.12.2 and 9.12.5. Check the applicable current texts and project requirements rather than relying on a paper certificate alone.
Verify the document and issuing body's accreditation in the official Federal Accreditation Service register.
1. Accreditation for the Relevant Standard
Inspect: the certification body's accreditation scope, not just the certificate. It should explicitly cover GOST R 57471-2017.
Request: a copy of the accreditation scope together with the certificate. Cross-check the organisation and accreditation number in the official register.
Warning signs: the standard is missing from the scope, the body cannot be found in the register, or the scope is withheld.
2. Photographs and Video of Successful Testing
Inspect: photographic and video attachments to the blast-test report. This is particularly important for higher protection classes and large-charge tests. For doors, normal opening after the blast matters because a jammed door can obstruct evacuation.
Request: photographs before and after testing and video of the detonation and subsequent door opening. Missing video is a reason to request further evidence.
Warning signs: a report saying only that no damage occurred, without images or video; no record of post-blast door opening.
3. Protection Class, Not a Trade Name
Inspect: the report's conclusion. It should assign a specific protection class and category under the standard, rather than repeat a commercial product designation.
A product name containing a class-like identifier is not itself evidence of an assigned protection class.
Request: the assigned class and category in the certificate and test report, not only the model or stock code.
Warning signs: a general statement of compliance or a pressure value without an assigned protection class and category.
4. Tested Specimen Dimensions
Inspect: the specimen dimensions in the report and the stated scope of the results. A small tested leaf does not establish the performance of a large gate.
Request: leaf and opening width and height, and confirmation that the proposed product falls within the tested and documented size range.
Warning signs: dimensions are absent or substantially smaller than the specified product.
Recommended Review Sequence
- Certificate and issuing body's accreditation scope.
- Test report with photographs and video.
- Assigned protection class and category.
- Specimen dimensions compared with the proposed product.
If any document is missing, request clarification and the missing evidence before accepting the product into the design. A responsible manufacturer should expect this request.
Check protection-class designations and their relationship to charge mass against the applicable edition of GOST R 57471-2017. This checklist is informational and does not replace expert or legal assessment. Official standards information: Russian Standardization Institute.